EVA
Manual · Katrina

TurboMak

Design of pumps and hydraulic turbines in a casing: impeller catalog by specific speed, velocity triangles, 3D geometry of the impeller and volute in STEP, off-design performance curves, three-zone domain, mesh and Fluent journal.

Version 2 · updated on Oct 24, 2026

Overview

TurboMak supports the preliminary design of a pump or hydraulic turbine in a casing: choice of impeller type, velocity triangles, 3D geometry, off-design performance and preparation of the simulation in ANSYS Fluent. It does not replace a detailed turbomachine design, but it delivers a geometry consistent with the operating point and all the files for the first simulation.

3D Geometry tab: impeller and fluid domain.
3D Geometry tab: impeller and fluid domain.

First steps

  1. Open Programs › Katrina and choose TurboMak. The program opens with an already-calculated pump example.
  2. In the sidebar, define whether the machine is a pump or a turbine and enter flow rate Q, speed N and head H.
  3. Go through the tabs from left to right: each tab uses the data from the previous ones.
  4. Save the project in .json to reopen or compare later.

The program tabs

TabWhat it does
Velocity trianglesCloses the triangles at stations 1 and 2 from D, b, β and the flow rate; shows U, Cm, Cu, W, C, α, Euler head, power and torque.
3D geometryGenerates the impeller (disc, hub, shroud and blades) and, optionally, the three-zone fluid domain with volute. Includes the Impeller models catalog and the 2D drawing with title block.
PerformanceH–Q, η–Q, P–Q and NPSHr curves from the 1D model, affinity map with iso-efficiency curves, system curve and design comparison.
MeshMesh sizes by level (from Coarse to Very fine), first layer from y+ and meshing scripts.
Fluent setupSolver journal: models, boundary conditions, MRF, interfaces and torque and head reports.
Validation (CFD)Compares CFD head, torque and efficiency with the design and points out the likely causes of the difference.

Calculation methods

Euler equation

Ht = (u2·cu2 − u1·cu1) / g     u = ω·r     cm = Q / (π·D·b)

For the turbine, station 2 is the rotor inlet, so the same expression gives the absorbed head with a positive sign.

Specific speed

nq = N·√Q / H3/4 (N in rpm, Q in m³/s, H in m)

The impeller catalog uses nq to indicate the types suitable for the operating point.

Off-design performance

The theoretical curve is corrected by Wiesner slip and by hydraulic losses (friction and inlet shock, which grows with the deviation from the design flow rate). Disc friction and volumetric efficiency complete the overall efficiency. The operating point is the intersection with the system curve Hs = Hst + k·Q².

Blade geometry

The camber line follows dθ/dr = 1/(r·tanβ), with β varying linearly from β1 to β2 (measured from the tangential). The leading edge is rounded and the trailing edge is trimmed at the outlet radius. The volute is sized by constant moment or constant velocity, with the tongue located numerically.

Results and export

  • STEP of the impeller and the domain (three solids: inlet, impeller and casing) — impeller axis along Y.
  • STL for visualization and 3D printing.
  • Scripts: SpaceClaim (imports the STEP and creates the Named Selections), Fluent Meshing and Fluent.
  • 2D drawing with plan view, triangles and meridional section.

From STEP to Fluent

  1. Generate the domain in the 3D Geometry tab and download the SpaceClaim script (it embeds the STEP).
  2. In SpaceClaim, run the script: it imports the geometry and creates the groups inlet, outlet, rotor, carcaca and the interfaces.
  3. In Fluent Meshing (Watertight), import the file and read the mesh journal.
  4. In Fluent, read the mesh and the solver journal. The calculation only starts once the interfaces and the MRF have been applied.

Automation with Ansys

Those who have ANSYS installed can run CAD, mesh and simulation from inside the program, without copying scripts. The scripts remain available in the Manual panel of each tab.

  1. Click Connect Ansys, at the top of the program, and download the connector. It uses the Python that comes with ANSYS: there is nothing to install.
  2. Open iniciar_conector.bat and paste into the program the token that appears in the window. One connection is valid for all tabs.
  3. Use the Automatic panel of each step, or Run through simulation.
  4. Follow the residuals and reports in the charts of the Fluent tab during the calculation.

Refinement, solver controls and optimization

  • Refinement of the region of interest: in Hydrokin and TurboMak, Body Size over the whole rotating domain; in WinGGen, a body of influence around the surfaces and the wake (boi.step file, imported as Body of Influence).
  • Solver controls: coupling (SIMPLE, SIMPLEC or Coupled), under-relaxation factors, 1st- or 2nd-order schemes, 1st-order start and bad-cell handling, in the sidebar of the Fluent tab.
  • Optimize mesh and solver: mesh and simulation rounds that read the residuals, the y+ on the walls of interest and the mesh quality, and adjust the design (1st layer, refinement, under-relaxation, iterations). It helps reach a simulation that converges; it does not replace the mesh independence study.

The connector runs only on your computer, accepts calls only with the token and executes only the CAD, mesh and simulation steps. The files are kept in Documentos\EVA-Ansys, ready to open by hand.

Scripts for ANSYS

The SpaceClaim, Fluent Meshing and Fluent scripts are generated for ANSYS 2026 R1 and tested here with API simulations and syntax checking. Some commands are still being validated on real installations — each script prints to the console what it did at each step. If something fails, send those lines to EVA.

Verification and limitations

  • The performance model is one-dimensional: it serves for preliminary design and for comparing alternatives, not for predicting final efficiency with test accuracy.
  • The blades are 2D (no 3D twist); high-specific-speed impellers require refinement in CAD.
  • In the turbine, the inlet pre-swirl (cylindrical coordinates) is a manual step in Fluent; the turbine journal does not start the calculation by itself.
Technical responsibility

The programs support the design but do not replace the analysis of a licensed professional. Check the input data and results, and use the report as a review document.

References

  • Gülich, J. F. Centrifugal Pumps. Springer.
  • Dixon, S. L.; Hall, C. A. Fluid Mechanics and Thermodynamics of Turbomachinery.
  • Stepanoff, A. J. Centrifugal and Axial Flow Pumps.
  • Wiesner, F. J. A review of slip factors for centrifugal impellers. J. Eng. Power, 1967.