EVA
Pompeii Thermal DesignVersion 2Updated on Oct 23, 2026

From the thermal balance to the exchanger in CAD and CFD.

Shell-and-tube exchangers and tube banks: thermal balance and sizing (LMTD, F factor, convection, pressure drop), 3D CAD with exact STEP and STL, domain and mesh for Fluent Meshing, Fluent setup and validation.

The problems Heater solves

Thermal balance

Heat duty and fluid temperatures must close — and respect the second law — before any geometry.

Equipment performance

LMTD, F factor, convection and pressure drop define whether the exchanger delivers what the process asks and whether the bundle fits in the shell.

From calculation to simulation

Domain with baffles and nozzles, mesh and Fluent setup usually have to be redone for each geometry.

Resources

What Heater offers

Thermal balance

Choose the variable to calculate: outlet temperature, flow rate or heat duty; temperature-cross check.

Thermal design

LMTD, F factor, internal (Dittus–Boelter, Gnielinski) and external (Kern, Zhukauskas) convection, overall coefficient with fouling and pressure drop per pass.

Geometry / CAD

Bundle with balanced passes, baffles, tubesheets, heads and nozzles in a 3D viewer; STEP with exact surfaces, STL and drawings.

Domain and mesh

Shell fluid with baffles and nozzles, conjugate model or periodic strip of the tube bank; Named Selections and prism layers from y+.

Simulation

Fluent journal with energy, turbulence, properties, inlets, tube walls and heat, temperature and pressure-drop reports.

Validation

CFD × analytical comparison and mesh independence (GCI).

How to use

From input data to result

  1. Choose the balance variableWhat Heater should calculate.
  2. Enter fluids and geometryHot fluid in the tubes, cold fluid in the shell, tubes and shell.
  3. Read the thermal designArea, coefficients, pressure drop and warnings.
  4. Check the CADBundle, baffles and nozzles in the 3D viewer; download the STEP.
  5. Generate domain, mesh and setupSpaceClaim, Fluent Meshing and Fluent — or the .zip package.
  6. ValidateBring the Fluent results back and compare them with the calculation.
Gallery

Heater screens

Click to enlarge. Use the keyboard arrows to navigate.

Geometry/CAD: bundle, baffles, heads and nozzles
Thermal design: temperatures, coefficients and losses
Shell-side fluid domain and mesh
Fluent setup
Specifications

Methods, standards and formats

What is implemented in Heater. The details of each method are in the manual.

See the methods in the manual →
Equipment
  • Shell and tube (1 shell, N tube passes) with segmental baffles
  • Tube banks in crossflow (inline or staggered)
Methods
  • LMTD with correction factor F; ε-NTU for cross-checking
  • Convection: Dittus–Boelter, Gnielinski, Kern, Zhukauskas
  • Pressure drop in the tubes (per pass, with returns) and in the shell
  • Air and water properties by table; oil and ethylene glycol constant (with a warning)
Geometry
  • STEP with exact planes, cylinders, lines and arcs (valid in OpenCascade)
  • Shell domain with the tubes as through holes, baffles and nozzles
Outputs
  • STEP, STL, drawings
  • SpaceClaim, Fluent Meshing and Fluent scripts, or .zip package
Frequently asked questions

About Heater

Didn't find the answer? See support or talk to EVA.

Does Heater replace a program like HTRI?

No. It is a preliminary sizing and CFD preparation tool, based on classic correlations (Kern, Zhukauskas). For the final design of process equipment, use methods such as Bell–Delaware and TEMA standards.

Why do oil and glycol warnings appear?

The properties of these fluids are constant (about 20 °C), and viscosity varies a lot with temperature.

Heater is part of Pompeii Thermal Design

Open the main program and choose the module inside it. Nothing needs to be installed.