EVA
Manual · Pompeii Thermal Design

Heater

Shell-and-tube exchangers and tube banks: thermal balance and sizing (LMTD, F factor, convection, pressure drop), 3D CAD with exact STEP and STL, domain and mesh for Fluent Meshing, Fluent setup and validation.

Version 2 · updated on Oct 23, 2026

Overview

Heater pre-sizes shell-and-tube heat exchangers and tube banks, generates the exact 3D geometry and prepares the simulation in Fluent.

Geometry/CAD of the shell-and-tube exchanger.
Geometry/CAD of the shell-and-tube exchanger.

First steps

  1. Open Programs › Pompeii › Heater.
  2. In Thermal design, choose the variable to calculate and enter the fluids, flow rates and temperatures.
  3. Adjust tubes, passes, baffles and shell; read the warnings.
  4. Continue to Geometry / CAD, Domain and mesh, Simulation and Validation.

Calculation methods

q = ṁq·cp,q·(Tq,e − Tq,s) = ṁf·cp,f·(Tf,s − Tf,e)
q = U·A·F·ΔTml    1/U = (1/hi)(De/Di) + Rwall + Rfoul + 1/he

The program warns when there is a temperature cross (second-law violation) or when F is undefined or below 0.4 for one shell — in those cases the result is not valid and more shells in series or another arrangement are needed. It also checks whether the calculated number of tubes fits in the shell.

Convection

Tubes: laminar (Nu = 4.36), transition (Gnielinski) and turbulent (Dittus–Boelter). Shell: Kern method; tube bank: Zhukauskas with Prandtl correction at the wall.

Pressure drop

Δptubes = Np·( f·L/Di + 4 )·ρV²/2

Results and export

  • STEP with exact surfaces and STL of the exchanger and the domain.
  • Shell domain (tubes as holes), conjugate model (wall and tube fluid) or periodic strip of the bank.
  • SpaceClaim, Fluent Meshing and Fluent scripts, individual or in a .zip package.
Scripts for ANSYS

The SpaceClaim, Fluent Meshing and Fluent scripts are generated for ANSYS 2026 R1 and tested here with API simulations and syntax checking. Some commands are still being validated on real installations — each script prints to the console what it did at each step. If something fails, send those lines to EVA.

Verification and limitations

  • The STEP files are valid in OpenCascade (positive volumes, edge deviation ~10⁻¹¹ mm); the SpaceClaim script was tested against the measured faces.
  • Simplified shell correlations (Kern): use more complete methods for the final design.
Technical responsibility

The programs support the design but do not replace the analysis of a licensed professional. Check the input data and results, and use the report as a review document.

References

  • Incropera, F. P. et al. Fundamentals of Heat and Mass Transfer. Wiley.
  • Kern, D. Q. Process Heat Transfer. McGraw-Hill.
  • Kakaç, S.; Liu, H. Heat Exchangers: Selection, Rating and Thermal Design.
  • Zhukauskas, A. Heat transfer from tubes in crossflow. Advances in Heat Transfer, 1972.