Hydrokinetic turbines: Betz, BEMT and the channel blockage effect
How much energy a river current can deliver, how BEMT designs the blade and why channel tests overestimate performance.
A hydrokinetic turbine extracts energy from the velocity of a current — from rivers, irrigation canals or tides — without a dam. Since water is about 830 times denser than air, a 2 m/s current carries the same power density as a wind of roughly 19 m/s.
Available power and the Betz limit
The Betz limit holds for a rotor in free flow. Well-designed axial rotors reach Cp of 0.40 to 0.46 at the design tip-speed ratio (λ = ωR/V around 5 to 6 for three blades). Drag rotors, such as the Savonius, stay well below, but are simple and robust.
BEMT: blade design
Blade element momentum theory (BEMT) divides the blade into rings and equates, in each one, the thrust and torque from the momentum balance to those produced by the lift and drag forces of the airfoil. To work over the whole operating range, it needs corrections:
- Prandtl at the tips and hub, for the flow through the disc between the blades;
- Glauert/Buhl for high induction factors, where momentum theory no longer holds;
- Viterna–Corrigan for the airfoil coefficients after stall.
The optimal chord and twist come from BEMT itself (Burton et al.); in practice, they are usually linearized to ease manufacturing.
Cavitation
Unlike wind, water can cavitate on the suction face of the blades, mainly at the tips and when the rotor is near the surface. The local cavitation number, σ = (patm + ρgh − pv)/(½ρW²), must exceed the airfoil's −Cp,min with margin — checked with the blade at its shallowest position.
Blockage: the channel pushes the water through the rotor
In a test channel or tunnel, the walls prevent the flow from going around the rotor freely. More water passes through the disc, and the measured Cp rises — sometimes beyond the Betz limit. When the blockage ratio (rotor area / section area) exceeds about 5%, IEC TS 62600-200 calls for correcting the results (Barnsley–Wellicome, Garrett–Cummins or Whelan methods).
In CFD
To sweep the Cp × λ curve, the moving reference frame (MRF) is fast; for transient behavior, use a sliding mesh with a step of about 1° of rotation per time iteration and averaging from the sixth revolution. With k-ω SST, keep y⁺ ≤ 1 on the blades and check mesh independence with the GCI.
Hydrokin brings together this whole path: BEMT or DMST, annual energy from the Weibull distribution, blockage, STEP geometry, domain, mesh and Fluent journal.
Read also
Shaft fatigue: from Goodman to elliptical ASME, without pitfalls
Why a shaft fails well below its static strength, how to build the alternating and mean stresses, and the most common errors in the Marin and stress-concentration factors.
Read the article →Load combinations in NBR 8681: why γ depends on the nature of the action
Ultimate and serviceability combinations, partial factors by type of permanent load and the mistakes that show up most in frame models.
Read the article →