NPSH: how to avoid cavitation at the pump suction
What available and required NPSH are, what reduces the margin at the suction and the design decisions that weigh the most.
Cavitation is the formation of vapor bubbles when the local pressure falls below the vapor pressure of the liquid. In a pump, this happens at the impeller inlet, where pressure is lowest. The bubbles collapse shortly afterward, in a region of higher pressure, with microjets that tear material from the blades. The result is noise, vibration, performance drop and erosion.
Available NPSH
Available NPSH (Net Positive Suction Head) is the energy above vapor pressure that the system delivers at the suction:
zs is positive when the liquid level is above the pump axis (flooded suction) and negative when below. hf,suction sums the distributed and local losses of the suction line.
Required NPSH
Required NPSH is a characteristic of the pump, given by the manufacturer as a function of flow rate — normally defined by a 3% drop in head. It grows with flow rate and with speed.
Since the catalog required NPSH already corresponds to a 3% performance drop, ANSI/HI 9.6.1 recommends NPSHa/NPSHr ratios between about 1.1 and 2.5, depending on the pump type and service; absent another reference, a minimum margin of 0.5 to 1 m is usual.
What reduces the margin
- Temperature: the vapor pressure of water rises from 2.3 kPa at 20 °C to 47 kPa at 80 °C.
- Altitude: atmospheric pressure drops about 1.2 kPa every 100 m.
- Long or narrow suction: the suction head loss comes straight off the available NPSH.
- Operating to the right of the design point: more flow means more required NPSH and more suction loss at the same time.
Design decisions
- Use a larger diameter on the suction than on the discharge and keep the velocity low (typically up to 1.5 m/s).
- Avoid bends and fittings right before the suction flange; use an eccentric reducer with the straight side up.
- Prefer flooded suction when the liquid is hot or the site is high.
- On high-speed pumps, consider a lower speed (4-pole motor): the required NPSH falls roughly with the square of the speed.
In Hydra
Hydra computes the available NPSH with the water properties by temperature and the real suction losses, compares it with the pump's required NPSH and includes the 4-pole alternative among the compared systems.
Read also
Shaft fatigue: from Goodman to elliptical ASME, without pitfalls
Why a shaft fails well below its static strength, how to build the alternating and mean stresses, and the most common errors in the Marin and stress-concentration factors.
Read the article →Load combinations in NBR 8681: why γ depends on the nature of the action
Ultimate and serviceability combinations, partial factors by type of permanent load and the mistakes that show up most in frame models.
Read the article →